Inspection Summary |
Chick Torrence
1124 Union Mill Rd.
Mt. Laurel, NJ 08054
856-234-7787
NJ License # 24GI00059600
|
Service/Repair Areas |
CHIMNEY |
|
Chimney 1 Type
When slight pressure was applied by hand, the chimney experienced some movement, indicating a
possible fracture.
We recommend a qualified chimney contractor evaluate for repairs.
Some damaged bricks were noted.
We recommend repairs.
Flue Lining
The clay tile flue liner is displaced ( separated ) . This will allow
deadly carbon monoxide gas ( CO ) into the living space.
Further evaluation by a qualified chimney contractor is
recommended.
Carbon Monoxide ( CO ) is a colorless, practically odorless and
tasteless gas or liquid. It results from incomplete oxidation of
carbon in combustion. It can cause sudden illness or death. It is
the leading cause of poisoning deaths in the United States.
Chimney Top
The chimney wash cap is damaged . This is a cement application
at the top of the chimney that surrounds the flue .
To prevent water intrusion, we recommend repairs by a qualified
masonry contractor.
A chimney screen cap was not in place. This is a caged type
device with a cap at the top of the flue. To prevent the intrusion of
rain, snow, rodents and fowl, we recommend installing a chimney
screen cap.
|


|
GUTTERS |
|
Gutter Type
Gutters full of debris.
Clean out immediately and repitch.
Gutters should be cleaned regularly to prevent water penetration , rot and roof damage. Periodically
inspect fastening components ( brackets and or gutter pins ), caulked joints and the condition of the
gutters , downspouts, elbows and extenders. Due to the position of the gutters, the condition of the fascia
is most often obscured.
|
|
GROUNDS |
|
Walks
Areas of damaged and uneven sidewalk and front walk were
noted. These areas present a trip hazard.
We recommend a qualified contractor evaluate for repairs.
Hand Rail
Loose hand rails were noted at the rear basement steps.
For safety, we recommend repairs.
Maintain this type of hand rail or railing.
Periodically sand, prime and paint or stain for personal safety and longer life.
Porches
The front porch has rotated ( separated ) from the foundation.
We recommend repairs by a qualified contractor.
Patio
The right patio has settled and is pitched toward the foundation, this will allow ponding, eventual water
entry and possible foundation wall damage. These areas can be mud - jacked. Mud - jacking is a sand and
clay mix that is pumped under pressure, through drilled holes, thereby lifting the low areas.
We recommend repairs by a qualified contractor.
Driveway
Deterioration of asphalt driveway was observed. These areas are
trip hazards.
We recommend repairs by a qualified contractor.
|



|
EXTERIOR |
|
Trim Work
The sheathing at the front right "bump out" is separated , this will
allow the intrusion of vermin and insects. We recommend repairs
and capping with aluminum.
Periodically inspect the Vinyl trim areas.
Repair and caulk when necessary to prevent water intrusion. This
is routine maintenance.
To prevent moisture damage, we recommend scrapping, sealing
and painting all wood trim areas periodically. This is a routine
maintenance issue.
|

|
INTERIOR |
|
Stairways
Loose hand rails were noted at the upper stairs and for safety , a hand rail is needed at the lower steps. A
damaged stair tread was noted at the lower steps.
For safety, we recommend repairs.
|
|
BATHROOM |
|
Bathroom Floor
Soft flooring was noted at the upper bathroom. This indicates moisture damage below - most likely to sub
flooring and possibly to framing members also.
We recommend further evaluation by a qualified flooring contractor.
Carpeting is not a good choice for a flooring material in the bathroom. The carpeting will hold moisture
which will breed mold.
Another flooring surface should be chosen, one that can be easily cleaned.
Toilet Bowl and Tank
Toilet is loose at it's base in the upper bathroom. For safety and to prevent water seepage, we recommend
a qualified licensed plumber evaluate for repairs .
Bathtub Faucets
The shower diverter is actively leaking.
We recommend repairs by a licensed plumber ( replace tub spout
and caulk ).
Bathtub Stopper
Tub stopper not working.
We recommend repairs by a licensed plumber.
|
 |
KITCHEN |
|
Kitchen Doors Windows
A damaged window screen was noted.
We recommend replacement.
The kitchen windows were inspected for proper operation and condition.
Kitchen Cabinets
Kitchen cabinets are loose and not properly fastened to wall above the refrigerator.
For safety, we recommend securing.
Counter Tops
Loose / detached counter tops were noted.
For safety, we recommend securing to cabinet tops ( Glue and or screws ).
To prevent moisture damage, it's a good idea to seal the bottom edge of the counter top above the
dishwasher with a product like " Kilz ".
|
|
FURNACE |
|
Heat Exchanger Flame Pattern
A dirty fan was noted.
As little as a 16th of an inch of dirt can cut the efficiency of the
furnace by 25 percent. A dirty fan indicates deferred maintenance.
We recommend a cleaning and servicing by a qualified heating
contractor.
Distribution System Material
The duct work is rusted at multiple areas. This is most likely from
condensation.
We recommend a qualified heating contractor evaluate for repairs.
For sanitary concerns , plan to have the entire system cleaned and
sanitized. These areas are a common source of mold build - up.
For more efficiency, insulate the duct work in unconditioned
spaces.
|


|
W. HEATER |
|
Water Heater Flue Pipe
Flue piping is showing evidence of rusting / spillage.
This is most usually from condensation - the hot air from the
furnace meeting the cold air in the chimney and condensing or a
possible blockage in the flue or chimney. Condensation is even
more of an issue with an exterior chimney ( the chimney is colder
and condensation occurs more rapidly ). A flue or chimney
blockage will cause poisonous carbon monoxide gas to enter the
living space.
We recommend a qualified heating contractor evaluate for
repairs.
Carbon Monoxide ( CO ) is a colorless, practically odorless and
tasteless gas or liquid. It results from incomplete oxidation of
carbon in combustion. It can cause sudden illness or death. It is
the leading cause of poisoning deaths in the United States.
The packing around the flue piping at the chimney connection is
deteriorated. To prevent the escape of harmful carbon monoxide
gas, we recommend adding fresh packing material ( furnace
cement ).
|
 |
ELECTRIC |
|
Main Electrical Service Wire
The main service wires vinyl jacket is split at the roof level. This
will allow water to trail down and into the main panel. This is a
dangerous condition.
We recommend their replacement by a qualified licensed
electrician.
Interior Wiring
Open splices ( exposed wiring connections ) were observed in the crawl space.
For safety, we recommend these connections be performed inside an approved work box with a cover. We
recommend a qualified licensed electrician evaluate for repairs .
|

|
CRAWL SPACE |
|
Crawl Space Foundation Walls
The foundation walls have been dug out to under the footings, the
block columns have exposed footings, temporary floor jacks were
noted, a scissor jack and major erosion was noted under the slab.
We recommend a full evaluation of all structural components by a
licensed engineer.
Termite Shelter Tubes were noted on the crawl space foundation
walls and termite damage was noted at the rear basement door
frame .
We recommend a termite treatment to prevent further infestation /
damage. We recommend all repairs be completed by a qualified
contractor. EXPECT POSSIBLE HIDDEN DAMAGE !!!
The termite evidence does not include hidden damage that may
exist. This inspection can not conclude any amount of damage that
exists inside an area that is not visible to the inspector.
Efflorescence was noted on the foundation walls.
This is a whitish mineral deposit often seen on the interior of
foundation walls. The presence of efflorescence indicates water
penetration, although it does not tell a great deal about the severity
of the problem or wether the problem is active. As water passes
through the wall, it dissolves salts in the masonry, concrete or
mortar, so that when the water arrives at the wall surface, it
contains a good deal of minerals in solution. The crystalline salt
deposit, known as efflorescence, is left as water is evaporated off
the wall surface. Since virtually all crawl space walls leak at some
point in time, the question is probably not " Will the crawl space
leak ?"but when. Since 90% of wet basement problems are
caused by surface water ( rain , snow , roof drainage ) collecting
around the building, the surface water issues should be addressed
first. Proper grading techniques are extremely important and
make sure all down spouts have elbows and extenders diverting
the water away 6 feet from the foundation and that the proper
grading techniques are implemented.
Efflorescence can be scrapped off and a water proofing paint
applied.
Crawl Space Ceiling Sub Floor
Moisture damage was noted to the sub flooring at the right side.
We recommend repairs by a qualified contractor.
|




|
Safety Areas
|
KITCHEN |
|
|
Range Oven
For safety, we recommend installing an anti- tip bracket at the rear of the oven.
Kitchen Wall Receptacles
For safety, we recommend installing GFCI protected outlets at ALL the kitchen outlets.
We recommend a licensed electrician install them.
|
|
W. HEATER |
|
Water Heater Cold Water Valve
No bonding wire present.
For safety, we recommend installing a bonding wire ( jumper wire ) between the hot and cold water pipes
above the water heater. Two adjustable clamps ( one half inch to one inch ) and one foot of ground wire (
no. 6 ). Cost is less than seven dollars and very simple to install.
|
|
Concern Areas
|
ROOF |
|
Approx. Age
This age bracket represents the waning stages of the roof 's serviceable life. This roof is 15 - 20 years old.
We recommend budgeting for replacement.
Composition shingle roofs generally last about 17 to 22 years.
|
|
EXTERIOR |
|
EXTERIOR
This inspection is not intended to address or include any
geological conditions , site stability information or determine the
flood plain conditions. For information concerning these
conditions, a geologist or soils engineer should be consulted. Any
reference to grade is limited to only areas around the exterior of
the exposed areas of the foundation or exterior walls. This
inspection is visual in nature and does not attempt to determine
drainage performance of the site or the condition of any
underground piping, including municipal water and sewer service
piping or septic systems. Decks and porches are often built close
to the ground, where viewing or access is impossible. These areas
as well as others too low to enter, or in some other manner not
accessible, are excluded from the inspection and are not
addressed in this report. We routinely recommend that inquiry be
made with the seller about knowledge of any prior foundation or
structural repairs.
As a means to help prevent water intrusion and as part of your
homeowner maintenance program, periodically examine windows,
door, porch and siding joints. Help prevent water seepage into
interior components.
We recommend the cutting back of all trees and vegetation
adjacent to the home. These are avenues for insect infestation and
will eventually damage the siding and or roofing materials.
Caulking
To prevent water entry, we recommend caulking all window, door,
trim , "J" channel intersections and siding intersections.
TO CAULK : MATERIALS : A CAULK GUN, A TUBE OF LATEX
CAULK, A RAZOR BLADE PAINT SCRAPPER, A SMALL
CONTAINER OF WATER.HOW TO : FIRST; SCRAPE OUT OLD
CAULK WITH PAINT SCRAPPER. SECOND; CUT TIP OF
CAULK TUBE NEAR THE END ( WE DON'T WANT TO OVER
CAULK - CUTTING CLOSER TO THE TUBE WILL GIVE US TOO
MUCH CAULK ) AT A 45 DEGREE ANGLE. THIRD; PLACE
TUBE INTO GUN. FOURTH; PLACE THE TUBE TIP INTO
CREVICE FARTHEST FROM YOU, MAKING CERTAIN THAT
THE ANGLED TIP IS POINTING INTO THE INTERSECTION,
AND DRAW IT SLOWLY TOWARD YOU. DO THIS AT ALL
AREAS. FIFTH; PLACE A FINGER INTO THE CONTAINER OF
WATER AND, STARTING AGAIN FROM FARTHEST AWAY,
SMOOTH THE CAULK WITH YOUR FINGER. THAT'S ALL
THERE IS TO IT!!!!
|


|
FURNACE |
|
FURNACE
Remind yourself to obtain a Utility or private service company Service plan prior to settlement ....... WE
ABSOLUTELY RECOMMEND IT ! Local Utility companies offer multiple appliance service plans.
A Home warranty is always a good idea.
The inspector is not equipped to inspect furnace heat exchangers for evidence of cracks or holes , as this
can only be done by dismantling the unit . This is beyond the scope of this inspection. Some furnaces are
made in such a way that inspection is impossible. The inspector can not light pilot lights or test safety
switches.
Filter System
A disposable filter was noted.
Filters should be changed monthly.
|
|
COOLING |
|
COOLING SYSTEM
As recommended for your heating system, remind yourself to obtain a utility or private service company
service plan prior to settlement ..... we recommend it. Local utility company offer multiple appliance
service plans. Your heating system needs regular maintenance just like you offer your automobile.
Air conditioning units have a life expectancy of approx. 14 - 17 yrs.
A Home warranty is always a good idea.
Condensate Drain
Condensate line drains into the utility sink. Even if an air gap is provided,in most jurisdictions, this may not
be a proper discharge point. We recommend you check with your local municipality to find out what is
allowed in your area. If it is permitted, care must be taken to keep the discharge tube above the level of the
utility sink to prevent siphoning. The best place for an air conditioning condensate discharge line is usually
considered to be outside the building onto the ground.
|
|
CRAWL SPACE |
|
Crawl Space Floor Vapor Barrier
A vapor barrier was not in place at the dirt floor.
A vapor barrier is recommended on top of the dirt floor to eliminate moisture penetration to the structural
components. A typical earth floor in a crawl space can add several gallons of moisture vapor to the house
air every day.
A 6 mil polyethylene sheet ( 6 / 1000 of an inch - not mils for millimeter ) may be installed at the dirt floor
perimeter and sealed with sand at the edges and held in place with gravel.
|
|
GARAGE |
|
Garage Type
The garage has been converted to living space.
We recommend obtaining all building Permits from the Township.
|
|